South Wales Steel Buildings

Grain store buildings

The one farm building where the walls are doing structural work, because the crop leans on them. Tell us roughly what you need to hold and you get engineered drawings and a price for the building — plus an honest figure for the floor, and the sum that tells you whether it is big enough.

Capacity, roughly
0.75 t/m³
Wheat, as a working figure. Floor area × depth × that, for a level bulk.
Wall panels
150–280 mm
The range precast suppliers commonly offer. Deeper bulks want the thicker end.
Typical slab
200 mm
Loader traffic, not the grain, is what decides it.
Planning route
Prior approval
A genuine grain store on a qualifying holding is agricultural development.

What you are actually buying

A flat store is the one building here that is structurally different from a shed with things in it. Everything else on this site stores something that sits still and stays where it is put. A bulk of grain leans on the walls, and it does it hard enough that the frame and the walling have to be designed for it. That is the whole game with a grain store: the frame, the walls and the floor are one system rather than a building with a floor in it.

Span and length are tonnage

Work out the tonnage you need to hold, decide the depth you can safely fill to, and the footprint falls out of the arithmetic. Do it in that order rather than picking a shed size and hoping it takes the harvest.

Wall height is the depth of the bulk

The retaining walls decide how deep you can go, and depth is worth far more than floor area — every extra metre of wall is tonnage across the whole footprint. It is also the number that has to be designed rather than guessed.

Eaves height is filling and emptying

Enough clearance above the wall for a loader bucket at full lift, or for the conveyor and the spout if it is being filled mechanically. Too tight at the eaves and you cannot fill the corners of your own store.

What you get asked to decide

  • Precast panel walls or a poured retaining wall, and how high they go
  • A drying floor with ducts, or laterals laid on the slab, or neither
  • Which end you tip at, and whether the doors are big enough for a loaded lorry
  • Bird and vermin proofing at the eaves, the ridge and the doors
  • Supplied for your own team to erect, or supplied and erected

There is one more choice underneath all of those: whether the frame iscold rolled or hot rolled. It changes the price, the lead time, whether you can put it up yourself, and what goes in the ground.

How it goes from here

Five steps, in this order. The fourth is the one nobody prices for you up front, which is why there is a calculator further down this page.

  1. Step 1

    Tell us roughly what you need

    Span, length and what it is for. Approximate is fine — nobody expects you to have decided, and it means the first reply can be useful rather than a list of questions.

  2. Step 2

    Drawings and a price for the frame

    The manufacturer prepares engineered drawings and quotes the building. That includes the pad foundation sizes, which no calculator can work out for you.

  3. Step 3

    Settle the planning position

    Prior approval on a qualifying agricultural holding, or a full application. Worth establishing before steel is ordered rather than after.

  4. Step 4

    Get the base in

    Site strip, level, stone and slab, ready and cured before the erectors arrive. This is the part you can price on this page today.

  5. Step 5

    Delivery and erection

    Delivered for your own team to put up, or supplied and erected. Both are normal; the difference is worth asking about at quote stage, not later.

Get a price for my grain store

Rough dimensions are enough to start. You get a reply the same day.

The walls are holding the crop back

Everything else on this site stores something that stays where it is put. Grain does not. A bulk leans on whatever is retaining it, and it leans hard — that is why a purpose-built flat store has proper retaining walls rather than sheeting down to the floor, and why the walls, the frame and the floor are one system rather than three separate decisions.

Precast panel systems are the common answer, and suppliers offer them from around 150mm thick for ordinary grain loads up to 280mm where the bulk is deeper or heaped. Which one you need is a design output, not a shopping choice. The reference for loads from stored bulk solids is Eurocode 1 Part 4, which covers silos and tanks — the point being that somebody with the standard open should be sizing this.

Pushed from inside

A shed built to keep rain off machinery was never designed to be shoved outward from within. Tipping grain against the side of one is the mistake that bends side rails and pulls stanchion bases.

If you are thinking of putting grain into a building you already have, that is a question for an engineer before it is a question for a haulier. Either the frame gets checked, or you build a retaining wall inside it that stands up on its own.

Working out what it holds

This is arithmetic and it is worth doing before anybody prices a frame. Floor area, multiplied by the depth you can fill to, multiplied by the bulk density of what you are storing. Wheat is commonly worked at around 0.75 tonnes per cubic metre — it varies with crop, variety and moisture, so it is a working figure rather than a promise.

A 15 by 30 metre store filled level to three metres is 450 square metres, times three metres, times 0.75 — about 1,000 tonnes. Change the wall height to four metres and the same footprint is holding a third more. That is why depth is worth more than floor area, and why the wall height is the number to get designed properly rather than the one to economise on.

Work in that order: the tonnage you need, then the depth you can safely go to, then the footprint. Picking a shed size first and hoping it takes the harvest is how farms end up with a heap outside under a sheet in October.

The loader decides the floor

Grain itself is an easy load — spread out, sitting still, no worse than bales. What decides the slab is the telehandler working in it: full bucket, turning on the spot, in the same few places all week. That is why a grain store floor sits with the machinery stores at 200mm with mesh rather than down with the hay barns.

If a drying floor is going in, that changes the job rather than the thickness. Ducts have to be designed and formed as part of the pour, laid out against how the store will actually be filled rather than spaced evenly for the look of it. Cutting ducts into a finished slab afterwards is a much worse job than forming them on the day, and you only get one day.

The roof that rains on the crop

A big uninsulated steel roof over a cool bulk of grain is a condensing surface. Warm moist air off the crop rises into the headspace, meets cold sheeting, condenses and drips back down onto the top of the heap. That is not a comfort problem — that is a rejection at the weighbridge.

It is a specification decision, made when the cladding is chosen: an anti-condensation lining or an insulated sheet, and ventilation that lets the headspace air out rather than trapping it. Both are cheap at the point of ordering and awkward to retrofit over a store with a thousand tonnes in it.

The same thinking applies to birds and vermin. Where the sheeting meets the eaves, how the ridge is closed and how the doors seal are the difference between a store that holds a crop to assurance standards and one that quietly does not.

Where you stand on planning

A genuine grain store on a working holding is agricultural development, so the prior approval route usually applies rather than a full planning application — provided the holding qualifies on size and the building is reasonably necessary for agriculture on it.

Storing somebody else's grain commercially is where it gets less straightforward, because the test attaches to agriculture on that unit. Worth being straight about at the prior approval stage rather than later.

In Wales, farm buildings get their permitted development rights from Part 6 of the 1995 General Permitted Development Order, which splits at 5 hectares — and the two halves are not the same right with different numbers on them.

On a unit of 5 hectares or more, Class A permits a new building, or the extension or alteration of one, if it is reasonably necessary for agriculture on that unit. Its ground area cannot exceed 465 square metres — counted together with anything else put up on the unit within 90 metres in the previous 2 years. It must be no more than 12 metres high and at least 25 metres from a trunk or classified road. England's limits are far larger; they do not apply here.

On a unit of 0.4 to under 5 hectares, Class B does not let you put up a new building at all. It permits a limited extension or alteration of a farm building you already have — no taller, no more than 10 per cent more volume, and no more than 465 square metres in all. With four hectares and nothing to extend, a new shed is a full planning application.

Where Class A applies, you are not applying for planning permission. You notify the council, which has 28 days to decide whether it wants to approve the siting, design and external appearance. You can start when it says it does not, when it approves them, or when 28 days pass without a reply — provided the building genuinely is permitted development in the first place.

One exclusion catches people: no building for livestock, and no slurry or sewage sludge store, within 400 metres of the curtilage of a protected building — broadly, a house that is not part of your own farm.

Two more things are Welsh. Construction of 100 square metres or more needs its drainage approved by the SuDS Approval Body even when it is permitted development. And in a National Park the park authority is the planning authority — here, the Bannau Brycheiniog National Park Authority or the Pembrokeshire Coast National Park Authority.

A summary, not planning advice. The legislation is SI 1995/418, Schedule 2, Part 6 as in force in Wales, checked against legislation.gov.uk on 23 September 2026. The full rules are on our planning guide for farm buildings in Wales. Confirm your own position with the authority that covers your site.

Work out the base for your grain store

Set to a grain store specification at 200mm. It prices the slab, the stone and the earthworks under the building. The retaining walls and any drying floor are separate items, and both want designing rather than estimating.

Building

Loader traffic, and stored grain pushing against the walls.

m
m

Slab

Set by the building type above. Change it if you know different.

mm

Each side. Leave at 0 if it finishes flush.

mm

Site

mm

High corner to low corner.

Balanced keeps the dug material on the plot and moves the least.

mm

Dig a trial hole and measure it. This shifts more muck than the slope does.

Concrete to order for the slab
52.0waste allowed, rounded to the half metre
Grain store · slab 246.4 m² at 200 mm · working platform 352.6
Ready-mix plant
Slab concrete
Net 49.3 m³ before waste
52.0
Quarry
Type 1 sub-base
Spread 188 mm loose to finish at 150 mm compacted
77.6t
Builders merchant
Mesh sheets
2.4 × 4.8 m sheets, 300 mm laps allowed
28sheets
Damp proof membrane
Laps and upstand included
276
Edge detail
Perimeter, for edge insulation or expansion joint
64.8m
Earthworks
Topsoil to strip
110.2 m³ once dug and loose
88.2
Cut
17.6
Fill
17.6

What this does not work out: the pad foundations

The concrete pads the stanchions sit on are sized by a structural engineer, not by a formula. They change with the span, the eaves height, the wind loading on your particular site and what the ground will bear. Anyone quoting you a pad size without a design has guessed it.

Want this priced properly?

Send us the job and we'll get you engineered drawings and a quote for the frame — with the pad sizes this tool can't work out. The figures above go with your enquiry, so you don't have to type them again.

Every enquiry gets a reply the same day, and your figures go with it. The building itself is designed and priced by South West Steel Buildings, our building partner, so your details go to them too, and they will be in touch. How we handle your details.

Common questions

How much grain will my store hold?
Floor area multiplied by the depth you can fill to, multiplied by the bulk density. Wheat is commonly worked at around 0.75 tonnes per cubic metre, though it varies with crop, variety and moisture, so treat it as a working figure rather than a guarantee. A 15 by 30 metre store filled level to 3 metres is 450 square metres by 3 metres by 0.75, which is roughly 1,000 tonnes. Work the sum in that order — tonnage first, then depth, then footprint — rather than picking a shed size and hoping it takes the harvest.
Can I store grain in an existing machinery shed?
Not against the walls, unless someone has checked them. This is the mistake that costs money. A bulk of grain pushes outward hard, and a building put up to keep rain off machinery was never designed to be shoved from the inside — the side rails, the cladding and the stanchion bases are not doing that job. Either build a retaining wall inside it that stands on its own, or get the frame checked by an engineer before you tip anything against it. The relevant design reference for loads from bulk solids is Eurocode 1 Part 4, which covers silos and tanks.
How high can grain store walls be?
As high as the walling system is designed for, and that is an engineering question rather than a preference. Precast panel suppliers commonly offer thicknesses from around 150mm for standard grain loads up to 280mm for deeper or heaped bulks, with systems available well above head height. Depth is worth more than floor area — every extra metre of wall height is tonnage across the whole footprint — which is exactly why it is the number to have designed rather than guessed.
Why does my grain store roof drip?
Because a large uninsulated roof over a cool bulk of grain is a condensing surface. Warm moist air in the headspace meets cold steel, condenses and runs back down onto the crop, which is a rejection risk rather than a nuisance. It is dealt with at the specification stage — an anti-condensation lining or an insulated sheet, plus ventilation of the headspace — and it is far cheaper to specify than to retrofit over a full store.
What does the floor of a grain store need to be?
What decides the floor is the loader, not the grain. Grain is a distributed load and an easy one; a telehandler turning on a full bucket in the same spot every day is not. A 200mm slab with mesh is the usual starting point for that reason. If a drying floor with ducts is going in, the duct layout has to be designed and formed as part of the pour — cutting ducts into a finished slab afterwards is a different and much worse job.
Do I need planning permission for a farm building in Wales?
It depends first on the size of the holding. On an agricultural unit of 5 hectares or more, Class A of Part 6 of the Town and Country Planning (General Permitted Development) Order 1995 permits a building reasonably necessary for agriculture on that unit, up to 465 square metres — counted together with anything else put up on the unit within 90 metres in the previous 2 years. It must be no more than 12 metres high (3 metres within 3 km of an aerodrome), at least 25 metres from a trunk or classified road, and a livestock building or slurry store must be at least 400 metres from a protected building. Before building you notify the council, which has 28 days to say whether it wants to approve the siting and design. On a unit of 0.4 to under 5 hectares Class B allows only a limited extension or alteration of an existing building, and a new building needs full planning permission; under 0.4 hectares there are no agricultural permitted development rights at all. England's larger limits do not apply in Wales.
Does a farm building in Wales need SAB approval?
If it covers 100 square metres or more and affects how rain soaks into the ground, yes — even when it is permitted development and needs no planning application. Since January 2019 construction of that size in Wales needs approval of its surface water drainage from the SuDS Approval Body, which is run by your local council, before work starts. Farm roofs and clean yards are included, and the rainwater off a new roof is usually the whole question.
Can I convert a farm building to a house in Wales without planning permission?
No. England has a permitted development right, Class Q, that lets some agricultural buildings become homes through a prior approval application. Wales has no equivalent: a barn conversion in Wales needs full planning permission from the local planning authority. Much of what is written about barn conversions online is about England, so check which country it was written for before relying on it.

Get a price for your grain store

Tell us the tonnage you need to hold and how deep you want to fill, and the footprint can be worked back from it. You get engineered drawings and a price, including the pad foundation sizes.